LP-2 / LP-3 Low Power RTU
A powerful solution for low power monitoring, control and data logging applications.
The LP-2 and LP-3 open up the world of high-tech communications and SCADA (supervisory control and data acquisition) functionality at a very affordable price!
The Kingfisher LP-2 / LP-3 Low Power RTU suits a wide range of remote monitoring applications that include environmental monitoring, gas metering, power metering and data logging. It's smart, easy to use, has ladder logic capability and has very flexible I/O and communication ports.
Very low power consumption is achieved using three modes - communicating, scanning and sleeping. The LP-2 / LP-3 RTU is packaged in a two part plastic enclosure that houses the electronics, communication interfaces and standby battery.
LP-2 / LP-3 Low Power RTUs are compatible with the entire family of Kingfisher Series II products and are configured using the same Toolbox software.
Overview
- Low power RTU suitable for remote installations
- Compatible with Series II option boards allow even greater flexibility
- Auxiliary 12V output can be used to power an external relay for control of peripheral devices such as high power radios
- Protocol support allows you to interface to a wide variety of systems using Kingfisher, MODBUS, DNP3, ASCII, TRIO, Inline, Omron and many more
- Can be used stand alone, and is also compatible with the field proven range of Kingfisher Series II
Features
![]() |
![]() |
![]() |
![]() |
![]() |
Very Low power consumption |
2 High speed pulse counters |
2 Magnetic latch relay outputs |
Up to 4 open-drain outputs |
4 low power analog inputs |
![]() |
![]() |
![]() |
![]() |
![]() |
Up to 4 communications ports |
Event logging |
Capture pictures from on site |
SMS control using a digital mobile phone |
Works with Series II |
Low power operation
- In sleep mode all I/O and communication devices are powered down and consumption is less than 10mW. In scanning mode the RTU has its I/O active and consumption is around 450mW. In communicating mode the RTU has all communications and I/O devices powered with the power consumption dependent on the activity and type of communication device.
- In low power applications the RTU should be configured to spend most of its time in sleep mode, some time in scanning mode and very little time in communicating mode. All sleep mode functions are programmable by the user using TOOLBOX Windows software.
The LP-2 and LP-3 are optimized for installations that require high-performance with low-power consumption.